When the dust removal accessory is in normal operation, the dust discharge device cannot stop working. Otherwise, the ash bucket will soon accumulate dust and cause it to overflow into the bag room, forcing the dust removal accessories to stop working.
If the electromagnetic pulse valve fails, it should be cleaned up in time. If there are impurities or moisture inside, it should be cleaned. If the diaphragm is damaged, it should be replaced in time.
When starting up, first turn on the compressed air to the gas storage tank, turn on the control power supply, and start the ash discharge equipment. If there are other equipment in the system, the downstream equipment should be started first.
When the machine is shut down, after the technical system is terminated, the dust removal accessories and the exhaust fan should be kept working for a period of time. When the dust removal accessory is stopped, it is necessary to repeatedly remove the dust removal accessory (can be manually cleaned), and remove the dust on the dust filter bag to prevent the bag from being affected by moisture.
The oil-water separator in the gas storage tank and the gas source triple joint should be drained once per shift. The oil-water separator should be cleaned every 3 to 6 months. The oil mister should always check the oil storage condition and refuel in time.