Before the centrifuge is operated, the power should be cut off and the centrifuge brake should be loosened first. You can manually turn the drum to see if there is any bite.
Check for other parts of the area for looseness and abnormality.
Turn on the power and start it in a clockwise direction (usually about 40-60 seconds from standstill to normal operation). Usually, each equipment must be empty for about 3 hours after it arrives at the factory. It can work without abnormal conditions.
The material should be placed as evenly as possible, and must be operated by a person, and the capacity must not exceed the rated amount.
Never overspeed the machine to avoid affecting the life of the machine.
After the machine is started, if there is an abnormal situation, it must be stopped for inspection and repaired if necessary.
The centrifuge is running at high speed, so do not touch the drum with the body to prevent accidents.
The mesh size of the filter cloth should be determined according to the size of the particles of the separated material, otherwise the separation effect will be affected. In addition, the filter cloth should be installed when the filter cloth is installed.
The sealing ring is embedded in the drum sealing groove to prevent material from getting in.
In order to ensure the normal operation of the centrifuge, please rotate the parts every 6 months.At the same time, check the running lubrication condition of the bearing, whether there is wear phenomenon, whether the components in the brake device are worn or not, and whether the bearing cover has oil leakage.
After the machine is used, it should be cleaned and kept clean.