Correct dust collector bag installation is very important to improve the life of the dust collector bag. The following are the recommended steps for installing the dust filter bag in the dust collector under the condition that the blow pipe is removed:

The installation of the filter bag should be carried out after the installation of the dust collector is completed (including thermal insulation and corrosion protection). Remove the blow tube and install the filter bag. When handling and storing the filter bag, care should be taken to prevent the filter bag from colliding with the surrounding hard objects and sharp corners. Do not step on the foot and press heavily to avoid damage.

1 Dust filter bag filter bag should pay attention to keep away from the fire when stored, to prevent moisture, direct sunlight and other strong light to prevent direct compression of heavy objects. Each filter bag should be checked before installation to prevent mechanical damage.

2 Dust filter bag installation personnel should dress meticulously. Clothes pockets must be clean. They cannot carry cigarettes, matches, lighters, keys, knives, etc. to avoid falling into the filter bag. (If debris falls into the filter bag, it must be removed). Do not wear shoes with nails or hard soles for installation. The person who installs the filter bag shall be fixed, the post shall be fixed, and the responsibility shall be clarified. Each person shall record the self-installed filter bag and sign the record book.

3 dust filter bag installation environment requirements: the installation site lighting enough light, the site is not allowed to store and installation unrelated equipment, debris and so on.

4 During the installation of dust filter bag filter bag, smoking is prohibited. Any form of welding or cutting of any part is forbidden. In case of power failure, lighting with lighters, matches, etc. is strictly forbidden. Every day after installation work, check the installation tools to avoid Missing into the filter bag damages the filter bag.

5 Dust filter bag installation filter bag requirements: It is recommended that two people install, one person will be folded vertically into the flower plate hole, another person to grasp and open the roll of filter bag. Cage frame should be centered, gently placed, ensure vertical when installed.

6 Dust filter bag installation inspection: After each filter bag is installed, check whether the joint seam is sealed and the sealing position is correct. Check if it is vertical from the ash bucket. If it is found that the bottom of the filter bag is touching or incorrect, make a record and straighten it under the guidance of someone.

7 After the dust filter bag is installed, the flower board should be gradually covered with a canvas to prevent debris from falling into the filter bag. When the injection pipe is installed, cover the board with a canvas to prevent damage to the filter bag.

8 Special attention should be paid to the installation of the dust filter bag: the center of the five parts of the nozzle, venturi nozzle, filter bag frame, dust filter bag, and flower board must be the same, and the deviation is less than 2mm.