Poor Installation

Improper installation of filter bags can also result in early bag failure and loss of cleaning effectiveness. For top load pulse jets, the most common install errors involve not seating the snap band properly. For a bottom load unit the bag not being folded over the top of the cage properly, poor clamp placement and tightening the clamp too much or too little are all common.

Additionally, duct design, turning vanes and deflection plates all contribute to uniform gas distribution to all filters. However poor installation of these elements can result in high airflow regions that will abrade the filter bags.  Rough handling such as bending or stepping on the bags during installation or improper tensioning can also cause holes or tears in the bag filters reducing their strength and durability.