Dust collection form: air box pulse

Filter bag specifications: diameter 130mm, length 2000-3500mm

Handling air volume: 5000T/D ≈100000m3 /h

Filtration wind speed: ≤1.2m/min

Inlet concentration: ≤1000g/Nm3

Export discharge ≤30mg/Nm3

Working temperature: ≤120°C

Import and export pressure difference: ≤1700Pa

Service life requirement: 2 years

Explosion protection requirements: antistatic