It is very important to use and operate the high temperature dust bag correctly. It has a direct relationship with the life of the bag filter. High temperature dust bag operation precautions:
1. Check the oil level of the centrifugal fan unloader, the oil level of the fan bearing box, check the looseness of the foot and fastening bolts, and check whether the pipeline damper is in the set switch position before starting the dust remover. Check if the pulse controller’s knob position is appropriate.
2. Start the precipitator before starting the crusher.
3, then start the grinder.
4. Turn on the pulse controller dust collector and start working.
5. During the operation of the dust collector, start the unloader before each class of parking to finish ash 5-10 minutes. The ash discharge pipe near the belt needs to be connected with a soft cloth barrel so that the dust will slowly flow on the belt to prevent secondary dust.
6. The electric valve pointer is on at 900 and the pointer at 00 is off.
7. The manual valve is turned clockwise to turn it counterclockwise to open.
8. The knob on the left side of the pulse controller controls the opening degree of the blower solenoid valve. The left rotation is small and the right rotation is larger.
9. The use, maintenance and cleaning of dust collectors are the responsibility of the crusher driver. And do a good job of dust collector operation records.