- Unit flow: 25-1200th, larger flow can be pralled by mutiple machines.
- Min working presure: 0.2MPa.
- Min working presure: 0.6MPa/1. OMPa/1.6MPa/2. 5MPa/4. OMPa.
- Max operating tempernture: 70℃.
- Filtration accuracy: 80-5000um.
- Control mode: Differential pressure, time and manual.
- Cleaning time: 60 seconds.
- Cleaning pressure loss: 0.01 -0.03MPa.
- Control voltage: Ac 220.
- Rated operating voltage: Three-phase,220V, 380V, 50HZ.
Description
DS brush-type self-cleaning filter is a fully automatic cleaning filter. A set of brushes is installed in the filter screen. The brushes are driven to rotate by a motor, and an electromagnetic drain valve is installed on the end cover of the filter. When cleaning, the signal from the differential pressure switch is transmitted to the control panel, the control panel opens the drain valve and starts the motor at the same time, driving the brush to rotate to brush off the sewage and impurities and discharge through the drain valve under the hydraulic force, no need to stop the flow for cleaning.
Performance
Model number | Pipe diameter (M M) | Filtered flow(t/h) | Filter area (cm²) | D ischarge capacity (mm ) | Secondary water flo w(KG) | M otor power (KW) | weight(KG) |
DSY5 | DN125 | 120 | 3000 | DN40 | 150 | 0.09 | 118 |
DSY 6 | DN150 | 160 | 5900 | DN4D | 150 | 0.18 | 165 |
D5Y8 | DN200 | 300 | 5900 | DN4D | 150 | 0.18 | 185 |
D5Y10 | DN 250 | 450 | 9500 | DN 50 | 200 | 0.37 | 285 |
Mounting Size
Model num ber | ØD(mm) | A (mm) | B (mm) | B” (mm) | C(mm) | C”(mm) | G (mm) | H(mm) | L (mm |
DSY5 | 273 | 650 | 832 | 1 300 | 552 | 650 | 225 | 225 | 1 500 |
DSY 6 | 273 | 800 | 1318 | 2150 | 920 | 1500 | 305 | 310 | 2800 |
DSY8 | 273 | 800 | 1318 | 2150 | 920 | 1 500 | 305 | 310 | 2800 |
DSY10 | 426 | 1200 | 1480 | 2300 | 940 | 1500 | 440 | 400 | 3000 |
Installation Diagram
Applications
- Cooling water treatment
cooling tower, make-up water system, air-conditioning system, and direct-flow system water filtration to reduce the generation of sediment in the heat exchanger and maintain its coling effect. - Raw water treatment
Filter surface river water, lake water, sea water, reservoir water, well water and groundwater to remove sand, bacteria, algae, organic matter, etc. - Filtration of industrial circulating water
In equipment that has certain requirements for water quality, such as: cooling towers, rolling mills, continuous casting machines, polishing, water pumps, solenoid valves, ion exchangers, spray fins, heat exchangers, or on water supply pipelines to filter out impurities in water and avoid clogging of pipelines, nozzles and other components. - Irrigation
Especially suitable for water sources with high impurity content, agricultural irrigation, spraying parks, golf courses, turf irrigation, etc.