Operating temperature:
For the bag filter, the use temperature depends on two factors, the first is the maximum temperature of the filter material, and the second is that the gas temperature must be above the dew point temperature. At present, due to the large number of glass fiber filters used, the maximum use temperature can reach 280°C. Cooling measures must be taken for gases above this temperature, and measures must be taken for gases below the dew point temperature. Now the PPS filter media is relatively large. The temperature is 170 degrees. For the bag filter, the relationship between the use temperature and the dust removal efficiency is not significant. This is different from the electrostatic precipitator. For the electrostatic precipitator, the temperature change will be The specific resistance that affects the dust affects the dust removal efficiency.